Extended Lead Wire AH Power Resistors - AHL Series
Extended Lead Wire AHL Power Resistors
Features
- High stability, strong construction.
- High power rating , small size and ultra precision.
- Offer both Standard winding & non-inductive winding.
- Extended lead wire design is easy to install and moreflexibility for designer.
General Specification:
- Wattage Range: 6 styles to choose ranging from 5 to 250 watts.
- Resistance Tolerance: 10%, 5%.
- Power range: 25W~150W.
|
| AHL Power Extended Lead Wire Series - Materials |
| ① |
Encapsulant |
Silicone |
 |
| End caps |
Stainless steel |
| Core |
Ceramic steatite or aluminum |
| Housing |
Aluminum with hard anodic coating |
| Element |
Copper-nickel alloy, nickel-chrome alloy or manganese copper |
| ② |
Wire (14AWG) |
AHL-25, AHL-25N |
AHL-50, AHL-50N |
AHL-150, AHL-150N |
AHL-150A, AHL-150AN |
| Length=160mm |
Length=340mm |
Length=500mm |
Length=300mm |
| ③ |
Terminals |
LVA2-250, Cu (Nickel-plate), W7.5 × L10mm |
| Notice: All values might be changed or modified, please consult factory for details. |
| AHL-25, AHL-50 Power Extended Lead Wire Series - Dimensions |
| Type |
Dimensions (Unit: mm) |
| E |
F |
G |
H |
M |
N |
P |
Q |
AHL-25 AHL-25N |
13 |
7 |
14.3 |
2 |
18.3 |
27 |
20 |
27 |
AHL-50 AHL-50N |
15.5 |
7.3 |
16 |
2 |
40 |
50 |
22 |
29 |
| Notice: All values might be changed or modified, please consult factory for details. |
| AHL-150, AHL-150A Power Extended Lead Wire Series - Dimensions |
| Type |
Dimensions (Unit: mm) |
| E |
F |
G |
H |
N |
P |
Q |
AHL-150 AHL-150N |
45 |
9.6 |
46 |
5 |
92 |
57 |
72 |
AHL-150A AHL-150AN |
26 |
11.5 |
27 |
3.5 |
97 |
37 |
48 |
| Notice: All values might be changed or modified, please consult factory for details. |
| LVA250 Terminals Dimensions (Unit: mm) |
| Suitable for 14~16AWG |
lmax=15A |
Unit: mm |
Tol.: ±0.2mm |
| ITEM |
NEMA-TAB |
Thickness |
B |
dΦ |
DΦ |
L |
H |
| LVA 2-250 |
0.8 × 6.35 |
0.4 |
7.4 |
2.3 |
4.3 |
21.0 |
10.0 |
| Notice: All values might be changed or modified, please consult factory for details. |
| AHL Power Extended Lead Wire Series - Electrical Specification |
| Type |
Wattage Rating (W) |
Resistance Range (Ω) |
Max. Working (V) |
Proper heat sink (Aluminum chassis) |
| Inductive |
Non-inductive |
Inductive |
Non-inductive |
| AHL-25 |
25 |
0.012~15K |
- |
500 |
- |
0.040 [1.0] Alum.Plate, 167 in2[1077 cm2] |
| AHL-25N |
25 |
- |
0.02~5.5K |
- |
300 |
0.040 [1.0] Alum.Plate, 167 in2[1077 cm2] |
| AHL-50 |
50 |
0.01~40K |
- |
1300 |
- |
0.059 [1.5] Alum.Plate, 291 in2[1877 cm2] |
| AHL-50N |
50 |
- |
0.02~12K |
- |
600 |
0.059 [1.5] Alum.Plate, 291 in2[1877 cm2] |
| AHL-150 |
150 |
0.4~50K |
- |
1900 |
- |
0.125 [3.2] Alum.Plate, 294 in2[1896 cm2] |
| AHL-150N |
150 |
- |
0.12~25K |
- |
1340 |
0.125 [3.2] Alum.Plate, 294 in2[1896 cm2] |
| AHL-150A |
150 |
0.4~50K |
- |
1900 |
- |
0.125 [3.2] Alum.Plate, 294 in2[1896 cm2] |
| AHL-150AN |
150 |
- |
0.12~25K |
- |
1340 |
0.125 [3.2] Alum.Plate, 294 in2[1896 cm2] |
| Notice: All values might be changed or modified, please consult factory for details. |
| Surface Temperature Versus Power Load (on Chassis) & Derating |
 |
 |
Derating is required to reduce chassis outing area and for high ambient temperatures.
Curves: A=5 & 10 watt units, unmounted.B=25 watt units, unmounted.C=50, 100 & 250 watt units, unmounted.
|
 |
REDUCED HEAT SINK DERATING: Derating is also required when recommended heat sink
area is reduced.
A = AHL-5 and AHL-10 size resistor.
B = AHL-25 size resistor
C = AHL-50, AHL-100 and AHL-250 size resistor |
| AHL Power Extended Lead Wire Series - Characteristics |
| Parameters |
Test Conditions |
Specifications |
| Vibration |
10c/s~50c/s~10c/s (1Min) - 2Hours each of paralleled and right angle |
Δ R±(1%+0.05Ω) Max. |
| Load Life |
Load Rating (chassis mounted)
(1.5Hour on 0.5Hour OFF) Repeat 1000Hours |
Δ R±(5%+0.1Ω) Max. |
| Heat Resistance |
260±5°C, 10±1Sec. |
Δ R±(1%+0.05Ω) Max. |
| Terminal Strength |
(1)Pull Test (30 sec Min)
AH-51kg, AH-10 2.3kg, AH-25, AH-50 4.5kg
(2)Torque Test (5~15sec)
AH-100 27kg-cm, AH-250 36kg-cm |
Δ R±(0.2%+0.05Ω) Max. |
| Dielectric Strength |
AH-5, AH-10, AH-25 1000V
AH-50 1500V
AH-100, AH-250 2000V |
Δ R±(0.5%+0.05Ω) Max. |
| Moisture Load Life |
Temp 40°C moisture 95% 1/10 × wattage rating
(1.5Hr on-0.5Hr OFF) - Repeat 200Hr |
Δ R±(1%+0.1Ω) Max. |
| Moistrue Resistance |
Temp 40°C moisture 95% DC 100V 500Hr |
Δ R±(1%+0.1Ω) Max. |
| Insulation Resistance |
Under the same test condition of Dielectric Strength, Load DC500V and measure the Insulation R. |
10MΩ Min. |
| Short Time Over Load |
5 × wattage rating-5sec. |
Δ R±(2%+0.1Ω) Max. |
| AHL-50 | 50W | L340 | 14AWG | R47 | K |
| 1 | 2 | 3 | 4 | 5 | 6 |
- 1 Part Number
| Normal Type | Non-inductive Type |
| AHL-25 | AHL-25N |
| AHL-50 | AHL-50N |
| AHL-150 | AHL-150N |
| AHL-150A | AHL-150AN |
- 3 Wire Length (min.)
| Part Number | Wire Length (min.) |
AHL-25 AHL-25N | L160 |
AHL-50 AHL-50N | L340 |
AHL-150 AHL-150N | L500 |
AHL-150A AHL-150AN | L300 |
- 6 Resistance Tolerance (%)
| Code | Resistance Tolerance (%) |
| K | ±10% |
| J | ±5% |
- 2 Rated Wattage
| Part Number | Rated Wattage |
AHL-25 AHL-25N | 25W |
AHL-50 AHL-50N | 50W |
AHL-150 AHL-150N | 150W |
AHL-150A AHL-150AN | 150W |
- 4 Wire Type : 14AWG
- 5 Max.Resistance Value (Ω)
| Code | Max.Resistance Value (Ω) |
| R47 | 0.47Ω |
| 4R7 | 4.7Ω |
| 470R | 470Ω |
| 4K7 | 4.7KΩ |
| 47K | 47KΩ |
| 47K3 | 47.3KΩ |
|